ÖVE/ÖNORM EN 61010-2-051

Issue date: 2016 03 01

Safety requirements for electrical equipment for measurement, control and laboratory use -- Part 2-051: Particular requirements for laboratory equipment for mixing and stirring (IEC 61010-2-051:2015) (english version)

This clause of Part 1 is applicable except as follows: 1.1 Scope Replacement: Replace the text in 1,1 by the following paragraph: This part of IEC 61010 is applicable...
Read more
Withdrawal on : 2024 08 01
This clause of Part 1 is applicable except as follows: 1.1 Scope Replacement: Replace the text in 1,1 by the following paragraph: This part of IEC 61010 is applicable to electrically operated laboratory equipment and its accessories for mechanical mixing and stirring, where mechanical energy influences the shape or size or homogeneity of materials and their accessories. Such devices may contain heating elements. NOTE If all or part of the equipment falls within the scope of one or more other Part 2 standards of IEC 61010 as well as within the scope of this standard, consideration is to be given to those other Part 2 standards. The standard for equipment which contain heating devices is IEC 61010-2-010.
OVE EN IEC 61010-2-051
2023 02 01
Safety requirements for electrical equipment for measurement, control and laboratory use -- Part 2-...
Norm
OVE EN IEC 61010-2-051
2023 02 01
Safety requirements for electrical equipment for measurement, control and laboratory use -- Part 2-...
Norm
ÖVE/ÖNORM EN 61010-2-051
2016 03 01
Safety requirements for electrical equipment for measurement, control and laboratory use -- Part 2-...
Norm
ÖVE/ÖNORM EN 61010-2-051
2004 09 01
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-05...
Norm
ÖVE EN 61010-2-51
1995 11 22
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-05...
Technische Regel
Historie aufklappen
Norm
OVE EN IEC 61010-2-051
Issue date : 2023 02 01
Safety requirements for electrical equipment for measurement, control and laboratory use -- Part 2-051: Particular requirements for laboratory equipment for mixing and stirring ( EN IEC 61010-2-051:2021) (german version)
Norm
OVE EN IEC 61010-2-051
Issue date : 2023 02 01
Safety requirements for electrical equipment for measurement, control and laboratory use -- Part 2-051: Particular requirements for laboratory equipment for mixing and stirring ( EN IEC 61010-2-051:2021) (english version)