Please select and order
€396.00
excl. VAT
CONFIGURE NOW
Norm

ÖVE/ÖNORM EN 60079-14

Issue date: 2014 11 01

Explosive atmospheres - Part 14: Electrical installations design, selection and erection (IEC 60079-14:2013) (english version)

This part of the IEC 60079 series contains the specific requirements for the design, selection, erection and initial inspection of electrical installations in, or associ...
Read more
Valid
Publisher:
Austrian Standards International
Format:
Digital | 150 Pages
Language:
English
This part of the IEC 60079 series contains the specific requirements for the design, selection, erection and initial inspection of electrical installations in, or associated with, explosive atmospheres. Where the equipment is required to meet other environmental conditions, for example, protection against ingress of water and resistance to corrosion, additional protection requirements may be necessary. The requirements of this standard apply only to the use of equipment under standard atmospheric conditions as defined in IEC 60079-0. For other conditions, additional precautions may be necessary, and the equipment should be certified for these other conditions. For example, most flammable materials and many materials which are normally regarded as non-flammable might burn vigorously under conditions of oxygen enrichment. These requirements are in addition to the requirements for installations in non-hazardous areas. This standard applies to all electrical equipment including fixed, portable, transportable and personal, and installations, permanent or temporary. This standard does not apply to – electrical installations in mines susceptible to firedamp; – inherently explosive situations and dust from explosives or pyrophoric substances (for example explosives manufacturing and processing); – rooms used for medical purposes; – electrical installations in areas where the hazard is due to flammable mist. No account is taken in this Standard of the toxic risks that are associated with flammable gases, liquids and dusts in concentrations that are usually very much less than the lower explosive limit. In locations where personnel may be exposed to potentially toxic concentrations of flammable material, appropriate precautions should be taken. Such precautions are outside the scope of this Standard.
ÖVE/ÖNORM EN 60079-14
2014 11 01
Explosive atmospheres - Part 14: Electrical installations design, selection and erection (IEC 60079-...
Norm
ÖVE/ÖNORM EN 60079-14/AC
2012 03 01
Explosive atmospheres - Part 14: Electrical installations design, selection and erection (Corrigendu...
Norm
ÖVE/ÖNORM EN 60079-14/AC
2012 03 01
Explosive atmospheres - Part 14: Electrical installations design, selection and erection (Corrigendu...
Norm
ÖVE/ÖNORM EN 60079-14
2009 07 01
Explosive atmospheres - Part 14: Electrical installations design, selection and erection (IEC 60079-...
Norm
ÖVE/ÖNORM EN 60079-14
2009 07 01
Explosive atmospheres - Part 14: Electrical installations design, selection and erection (IEC 60079-...
Norm
ÖVE/ÖNORM EN 61241-14
2005 08 01
Electrical apparatus for use in the presence of combustible dust - Part 14: Selection and installati...
Norm
ÖVE/ÖNORM EN 60079-14
2004 08 01
Electrical apparatus for explosive gas atmospheres - Part 14: Electrical installations in hazardous ...
Norm
ÖVE/ÖNORM EN 60079-14
2000 07 01
Electrical apparatus for explosive gas atmospheres - Part 14: Electrical installations in hazardous ...
Norm
Historie aufklappen