Norm

ÖNORM EN ISO 80601-2-72

Issue date: 2016 03 01

Medical electrical equipment - Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients (ISO 80601-2-72:2015)

IEC 60601-1:205+AMD1:2012, Clause 1 applies, except as follows: IEC 60601-1:2005+AMD1:2012, 1.1 is replaced by: This part of ISO 80601 applies to the BASIC SAFETY and ...
Read more
Withdrawn : 2024 01 01
Publisher:
Austrian Standards International
Format:
Digital | 113 Pages
Language:
German | English | Download GER/ENG
Optionally co-design standards:
IEC 60601-1:205+AMD1:2012, Clause 1 applies, except as follows: IEC 60601-1:2005+AMD1:2012, 1.1 is replaced by: This part of ISO 80601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of a VENTILATOR in EQUIPMENT: combination with its ACCESSORIES, hereafter referred to as MECARE ENVIRONMENT; — intended for use in the HOME HEALTH — intended for use by a LAY OPERATOR; — intended for use with PATIENTS who are dependent on mechanical ventilation for their life support. This part of ISO 80601 is also applicable to those ACCESSORIES intended by their MANUFACTURER to be connected to a VENTILATOR BREATHING SYSTEM or to a VENTILATOR where the characteristics of those ACCESSORIES can affect the BASIC SAFETY or ESSENTIAL PERFORMANCE of the VENTILATOR. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this part of ISO 80601 are not covered by specific requirements in this part of ISO 80601 except in IEC 60601-1:2005+AMD1:2012, 7.2.13 and 8.4.1. This part of ISO 80601 is not applicable to continuous positive airway pressure (CPAP) ME EQUIPMENT, high-frequency jet ventilators (HFJVs), and high-frequency oscillatory ventilators (HFOVs). This part of ISO 80601 does not specify the requirements for cuirass and “iron-lung” VENTILATORS. This part of ISO 80601 does not specify the requirements for VENTILATORS or ACCESSORIES intended for critical care applications, which are given in ISO 80601-2-12. This part of ISO 80601 does not specify the requirements for VENTILATORS or ACCESSORIES intended for anaesthetic applications, which are given in ISO 80601-2-13. This part of ISO 80601 does not specify the requirements for VENTILATORS or ACCESSORIES intended for emergency and transport which are given in ISO 10651-3. This part of ISO 80601 does not specify the requirements for VENTILATORS or ACCESSORIES intended for home-care ventilatory support equipment (intended only to augment the ventilation of spontaneously breathing PATIENTS), which are given in ISO 10651-6. This part of ISO 80601 does not specify the requirements for obstructive sleep apnoea therapy ME EQUIPMENT, which are given in ISO 80601-2-70. This part of ISO 80601 is a particular International Standard in the IEC 60601-1 and ISO/IEC 80601 series of standards.
ÖNORM EN ISO 80601-2-72
2024 01 01
Medical electrical equipment - Part 2-72: Particular requirements for basic safety and essential per...
Norm
ÖNORM EN ISO 80601-2-72
2016 03 01
Medical electrical equipment - Part 2-72: Particular requirements for basic safety and essential per...
Norm
ÖNORM EN ISO 10651-2
2011 07 01
Lung ventilators for medical use - Particular requirements for basic safety and essential performanc...
Norm
ÖNORM EN ISO 10651-2
2009 09 01
Lung ventilators for medical use - Particular requirements for basic safety and essential performanc...
Norm
ÖNORM EN ISO 10651-2
2004 10 01
Lung ventilators for medical use - Particular requirements for basic safety and essential performanc...
Norm
ÖNORM EN 794-2
1997 10 01
Lung ventilators - Part 2: Particular requirements for home care use
Norm
Historie aufklappen
Norm
ISO 32:1977
Issue date : 1977 05 01
Gas cylinders for medical use — Marking for identification of content
Norm
ISO 594-1:1986
Issue date : 1986 06 12
Conical fittings with a 6 % (Luer) taper for syringes, needles and certain other medical equipment — Part 1: General requirements
Norm
ISO 594-2:1998
Issue date : 1998 09 03
Conical fittings with 6 % (Luer) taper for syringes, needles and certain other medical equipment — Part 2: Lock fittings
Norm
ISO 3744:2010
Issue date : 2010 09 22
Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Engineering methods for an essentially free field over a reflecting plane
Norm
ISO 4135:2001
Issue date : 2001 08 02
Anaesthetic and respiratory equipment — Vocabulary
Norm
ISO 4871:1996
Issue date : 1996 12 19
Acoustics — Declaration and verification of noise emission values of machinery and equipment
Norm
ISO 5356-1:2004
Issue date : 2004 05 12
Anaesthetic and respiratory equipment — Conical connectors — Part 1: Cones and sockets
Norm
ISO 5359:2008
Issue date : 2008 05 28
Low-pressure hose assemblies for use with medical gases
Norm
ISO 5367:2000
Issue date : 2000 06 08
Breathing tubes intended for use with anaesthetic apparatus and ventilators
Norm
ISO 7000:2014
Issue date : 2014 01 20
Graphical symbols for use on equipment — Registered symbols
Norm
ISO 7010:2011
Issue date : 2011 05 27
Graphical symbols — Safety colours and safety signs — Registered safety signs
Norm
ISO 7396-1:2007
Issue date : 2007 03 28
Medical gas pipeline systems — Part 1: Pipeline systems for compressed medical gases and vacuum (Corrected version 2007-03)
Norm
ÖNORM EN ISO 80601-2-72
Issue date : 2024 01 01
Medical electrical equipment - Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients (ISO 80601-2-72:2023)
Norm
ISO 80601-2-72:2015
Issue date : 2015 09 01
Medical electrical equipment — Part 2-72: Particular requirements for basic safety and essential performance of home healthcare environment ventilators for ventilator-dependent patients