ÖNORM EN ISO 80601-2-56

Issue date: 2018 01 01

Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement (ISO 80601-2-56:2017)

This document applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of a CLINICAL THERMOMETER in combination with its ACCESSORIES, hereafter referred to as ME EQUIPMENT. ...
Read more
Withdrawn : 2020 08 15
Publisher:
Austrian Standards International
Format:
Digital | 69 Pages
Language:
German | English | Download GER/ENG
Optionally co-design standards:
This document applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of a CLINICAL THERMOMETER in combination with its ACCESSORIES, hereafter referred to as ME EQUIPMENT. This document specifies the general and technical requirements for electrical CLINICAL THERMOMETERS. This document applies to all electrical CLINICAL THERMOMETERS that are used for measuring the BODY TEMPERATURE of PATIENTS. CLINICAL THERMOMETERS can be equipped with interfaces to accommodate secondary indicators, printing equipment, and other auxiliary equipment to create ME SYSTEMS. This document does not apply to auxiliary equipment. ME EQUIPMENT that measures a BODY TEMPERATURE is inside the scope of this document. This document does not specify the requirements for screening thermographs intended to be used for the individual non-invasive human febrile temperature screening of groups of individual humans under indoor environmental conditions, which are given in IEC 80601-2-59. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005+A1:2012, 7.2.13 and 8.4.1.
ÖNORM EN ISO 80601-2-56
2020 08 15
Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential per...
Norm
ÖNORM EN ISO 80601-2-56
2018 01 01
Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential per...
Norm
ÖNORM EN ISO 80601-2-56
2013 01 01
Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential per...
Norm
ÖNORM EN 12470-4
2009 09 15
Clinical thermometers - Part 4: Performance of electrical thermometers for continuous measurement
Norm
ÖNORM EN 12470-3
2009 09 15
Clinical thermometers - Part 3: Performance of compact electrical thermometers (non-predictive and p...
Norm
ÖNORM EN 12470-5
2003 08 01
Clinical thermometers - Part 5: Performance of infra-red ear thermometers (with maximum device)
Norm
ÖNORM EN 12470-4
2001 02 01
Clinical thermometers - Part 4: Perfomance of electrical thermometers for continuous measurement
Norm
ÖNORM EN 12470-3
2000 07 01
Clinical thermometers - Part 3: Performance of compact electrical thermometers (non-predictive and p...
Norm
Historie aufklappen
Norm
ISO 14155:2011
Issue date : 2011 01 21
Clinical investigation of medical devices for human subjects — Good clinical practice
Norm
ISO 14937:2009
Issue date : 2009 10 14
Sterilization of health care products — General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices
Norm
ISO 15223-1:2016
Issue date : 2016 11 02
Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied — Part 1: General requirements (Corrected version 2017-03)
Norm
ISO 17664:2004
Issue date : 2004 02 25
Sterilization of medical devices — Information to be provided by the manufacturer for the processing of resterilizable medical devices
Norm
ÖNORM EN ISO 80601-2-56
Issue date : 2020 08 15
Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement (ISO 80601-2-56:2017 + Amd 1:2018) (consolidated version)