Please select and order
€84.27
excl. VAT
CONFIGURE NOW
Norm

ÖNORM EN ISO 5167-6

Issue date: 2020 01 15

Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 6: Wedge meters (ISO 5167-6:2019)

This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determi...
Read more
Withdrawn : 2023 07 01
Publisher:
Austrian Standards International
Format:
Digital | 20 Pages
Language:
German | English | Download GER/ENG
This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. NOTE 1 As the uncertainty of an uncalibrated wedge meter can be too large for a particular application, it could be deemed essential to calibrate the flow meter according to Clause 7. This document gives requirements for calibration which, if applied, are for use over the calibrated Reynolds number range. Clause 7 could also be useful guidance for calibration of meters of similar design but which fall outside the scope of this document. It also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167-1. This document is applicable only to wedge meters in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. Uncalibrated wedge meters can only be used within specified limits of pipe size, roughness, beta (or wedge ratio) and Reynolds number. It is not applicable to the measurement of pulsating flow. It does not cover the use of uncalibrated wedge meters in pipes whose internal diameter is less than 50 mm or more than 600 mm, or where the pipe Reynolds numbers are below 1 × 10^4.
ÖNORM EN ISO 5167-6
2023 07 01
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-secti...
Norm
ÖNORM EN ISO 5167-6
2020 01 15
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-secti...
Norm
Norm
ISO 4006:1991
Issue date : 1991 05 16
Measurement of fluid flow in closed conduits — Vocabulary and symbols
Norm
ISO 5167-1:2003
Issue date : 2003 02 24
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 1: General principles and requirements
Norm
ISO 5168:2005
Issue date : 2005 06 15
Measurement of fluid flow — Procedures for the evaluation of uncertainties
Norm
ISO/IEC 17025:2017
Issue date : 2017 11 29
General requirements for the competence of testing and calibration laboratories (Corrected version 2017-11)
Technische Regel
ISO/IEC Guide 98-3:2008
Issue date : 2008 09 30
Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) (Corrected version 2010-11)
Norm
ÖNORM EN ISO 5167-6
Issue date : 2023 07 01
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 6: Wedge meters (ISO 5167-6:2022)
Norm
ISO 5167-6:2019
Issue date : 2019 02 04
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 6: Wedge meters