Norm

ÖNORM EN ISO 17294-2

Issue date: 2005 02 01

Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of 62 elements (ISO 17294-2:2003)

This part of ISO 17294 specifies a method for the determination of the elements aluminium, antimony, arsenic, barium, beryllium, bismuth, boron, cadmium, caesium, calciu...
Read more
Withdrawn : 2017 01 15
Publisher:
Austrian Standards International
Format:
Digital | 25 Pages
Language:
German | English | Download GER/ENG
Optionally co-design standards:
This part of ISO 17294 specifies a method for the determination of the elements aluminium, antimony, arsenic, barium, beryllium, bismuth, boron, cadmium, caesium, calcium, cerium, chromium, cobalt, copper, dysprosium, erbium, europium, gadolinium, gallium, germanium, gold, hafnium, holmium, indium, iridium, lanthanum, lead, lithium, lutetium, magnesium, manganese, molybdenum, neodymium, nickel, palladium, phosphorus, platinum, potassium, praseodymium, rubidium, rhenium, rhodium, ruthenium, samarium, scandium, selenium, silver, sodium, strontium, terbium, tellurium, thorium, thallium, thulium, tin, tungsten, uranium, vanadium, yttrium, ytterbium, zinc, and zirconium in water [for example drinking water, surface water, groundwater, wastewater and eluates (9.2)]. Taking into account the specific and additionally occurring interferences, these elements can also be determined in digests of water, sludges and sediments (for example digests of water as specified in ISO 15587-1 or ISO 15587-2). The working range depends on the matrix and the interferences encountered. In drinking water and relatively unpolluted waters, the limit of application is between 0,1 ug/l and 1,0 ug/l for most elements (see Table 1). The detection limits of most elements are affected by blank contamination and depend predominantly on the laboratory air-handling facilities available. The lower limit of application is higher in cases where the determination is likely to suffer from interferences (see Clause 5) or in case of memory effects (see 8.2 of ISO 17294-1).
ÖNORM EN ISO 17294-2
2017 01 15
Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Deter...
Norm
ÖNORM EN ISO 17294-2
2005 02 01
Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Deter...
Norm
Norm
ISO 17294-1:2004
Issue date : 2004 09 08
Water quality — Application of inductively coupled plasma mass spectrometry (ICP-MS) — Part 1: General guidelines (Corrected version 2005-03)
Norm
ISO 5667-3:2003
Issue date : 2003 12 09
Water quality — Sampling — Part 3: Guidance on the preservation and handling of water samples
Norm
ISO 8466-1:1990
Issue date : 1990 03 01
Water quality — Calibration and evaluation of analytical methods and estimation of performance characteristics — Part 1: Statistical evaluation of the linear calibration function
Norm
ÖNORM EN ISO 15587-1
Issue date : 2002 07 01
Water quality - Digestion for the determination of selected elements in water - Part 1: Aqua regia digestion (ISO 15587-1:2002)
Norm
ÖNORM EN ISO 15587-2
Issue date : 2002 07 01
Water quality - Digestion for the determination of selected elements in water - Part 2: Nitric acid digestion (ISO 15587-2:2002)
Norm
ÖNORM EN ISO 3696
Issue date : 1995 08 01
Water for analytical laboratory use - Specifications and test methods (ISO 3696:1987)
Norm
ÖNORM EN ISO 5667-1
Issue date : 2007 04 01
Water quality - Sampling - Part 1: Guidance on the design of sampling programmes and sampling techniques (ISO 5667-1:2006)
Norm
ISO 3696:1987
Issue date : 1987 04 09
Water for analytical laboratory use — Specification and test methods
Norm
ISO 5667-1:1980
Issue date : 1980 09 01
Water quality — Sampling — Part 1: Guidance on the design of sampling programmes
Norm
ISO 5667-2:1991
Issue date : 1991 07 18
Water quality — Sampling — Part 2: Guidance on sampling techniques
Norm
ISO 5667-3:2018
Issue date : 2018 05 11
Water quality — Sampling — Part 3: Preservation and handling of water samples
Norm
ISO 8466-1:1990
Issue date : 1990 03 01
Water quality — Calibration and evaluation of analytical methods and estimation of performance characteristics — Part 1: Statistical evaluation of the linear calibration function
Norm
ISO 15587-1:2002
Issue date : 2002 02 28
Water quality — Digestion for the determination of selected elements in water — Part 1: Aqua regia digestion
Norm
ISO 15587-2:2002
Issue date : 2002 02 26
Water quality — Digestion for the determination of selected elements in water — Part 2: Nitric acid digestion
Norm
ISO 17294-1:2004
Issue date : 2004 09 08
Water quality — Application of inductively coupled plasma mass spectrometry (ICP-MS) — Part 1: General guidelines (Corrected version 2005-03)
Norm
ÖNORM EN ISO 17294-2
Issue date : 2017 01 15
Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes (ISO 17294-2:2016)
Norm
ISO 17294-2:2003
Issue date : 2003 09 10
Water quality — Application of inductively coupled plasma mass spectrometry (ICP-MS) — Part 2: Determination of 62 elements