Please select and order
€120.67
excl. VAT
CONFIGURE NOW
Norm

ÖNORM EN ISO 16017-2

Issue date: 2003 10 01

Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 2: Diffusive sampling (ISO 16017-2:2003)

This part of ISO 16017 gives general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air. It is applicable to indoor, ambient and workplac...
Read more
Valid
Publisher:
Austrian Standards International
Format:
Digital | 47 Pages
Language:
German | English | Download GER/ENG
Optionally co-design standards:
This part of ISO 16017 gives general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air. It is applicable to indoor, ambient and workplace air. This part of ISO 16017 is applicable to a wide range of VOCs, including hydrocarbons, halogenated hydrocarbons, esters, glycol ethers, ketones and alcohols. A number of sorbents1) are recommended for the sampling of these VOCs, each sorbent having a different range of applicability. Very polar compounds generally require derivatisation; very low boiling compounds are only partially retained by the sorbents and can only be estimated qualitatively. Semi-volatile compounds are fully retained by the sorbents, but may only be partially recovered. This part of ISO 16017 is applicable to the measurement of airborne vapours of VOCs in a mass concentration range of approximately 0,002 mg/m3 to 100 mg/m3 individual organic for an exposure time of 8 h, or 0,3 ug/m3 to 300 ug/m3 individual organic for an exposure time of four weeks. The upper limit of the useful range is set by the sorptive capacity of the sorbent used and by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capability of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of analyte and/or interfering artefacts on the sorbent tubes. Artefacts are typically subnanogram for well-conditioned Tenax GR and carbonaceous sorbents such as Carbopack/Carbotrap type materials, carbonized molecular sieves such as Spherocarb and pure charcoals. Artefacts are typically at low nanogram levels for Tenax TA and at 5 ng to 50 ng levels for other porous polymers such as Chromosorbs and Porapaks.
ÖNORM EN ISO 16017-2
2003 10 01
Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent t...
Norm
Norm
ISO 16000-1:2004
Issue date : 2004 07 02
Indoor air — Part 1: General aspects of sampling strategy
Norm
ISO 16000-1:2004
Issue date : 2004 07 02
Indoor air — Part 1: General aspects of sampling strategy
Norm
ISO 16017-2:2003
Issue date : 2003 05 16
Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 2: Diffusive sampling