Please select and order
€98.22
excl. VAT plus shipping costs
CONFIGURE NOW
Norm
ÖNORM EN ISO 16000-10
Issue date: 2006 06 01
Indoor air - Part 10: Determination of the emission of volatile organic compounds from building products and furnishing - Emission test cell method (ISO 16000-10:2006)
This part of ISO 16000 specifies a general laboratory test method for determination of the area specific
emission rate of volatile organic compounds (VOCs) from newly pr...
Read more
Valid
Publisher:
Austrian Standards International
Format:
Digital | 21 Pages
Language:
German
| English
| Download GER/ENG
Optionally co-design standards:
ICS
This part of ISO 16000 specifies a general laboratory test method for determination of the area specific
emission rate of volatile organic compounds (VOCs) from newly produced building products or furnishing
under defined climate conditions. The method can in principle also be applied to aged products. The emission
data obtained can be used to calculate concentrations in a model room.
According to the definition of an emission test cell, it is also possible to perform non-destructive emission
measurements on building products on-site in buildings. However, the procedure for such measurements is
not described in this part of ISO 16000.
Sampling, transport and storage of materials to be tested, and preparation of test specimens are described in
ISO 16000-11. Air sampling and analytical methods for the determination of VOCs are described in
ISO 16000-6 and ISO 16017-1[20].
An example of an emission test cell is described in Annex C of this part of ISO 16000.
For the determination of formaldehyde emissions from wood-based panels, refer to EN 717-1:2004 [21] and
ISO 12460-1 [1]. However, this part of ISO 16000 is also applicable to wood-based panels and other building
products in order to determine the emission rate of formaldehyde. The measurement procedure for
formaldehyde is described in ISO 16000-3 [2].
ÖNORM EN ISO 16000-10
2006 06 01
Indoor air - Part 10: Determination of the emission of volatile organic compounds from building prod...
Norm
↖
ÖNORM ENV 13419-2
1999 11 01
Building products - Determination of the emission of volatile organic compounds - Part 2: Emission t...
Vornorm
ÖNORM ENV 13419-2
1999 02 01
Building products - Determination of the emission of volatile organic compounds - Part 2: Emission t...
Vornorm Entwurf
Norm
ISO 16000-11:2006
Issue date :
2006 01 30
Indoor air — Part 11: Determination of the emission of volatile organic compounds from building products and furnishing — Sampling, storage of samples and preparation of test specimens
Norm
ISO 554:1976
Issue date :
1976 08 01
Standard atmospheres for conditioning and/or testing — Specifications
Norm
ISO 16000-11:2006
Issue date :
2006 01 30
Indoor air — Part 11: Determination of the emission of volatile organic compounds from building products and furnishing — Sampling, storage of samples and preparation of test specimens
Norm
ISO 16000-10:2006
Issue date :
2006 01 30
Indoor air — Part 10: Determination of the emission of volatile organic compounds from building products and furnishing — Emission test cell method (Corrected version 2006-06)