Please select and order
€171.12
excl. VAT plus shipping costs
CONFIGURE NOW
Norm

ÖNORM EN ISO 12417-1

Issue date: 2016 02 01

Cardiovascular implants and extracorporeal systems - Vascular device-drug combination products - Part 1: General requirements (ISO 12417-1:2015)

This part of ISO 12417 specifies requirements for vascular device-drug combination products (VDDCPs) based upon current technical and medical knowledge. VDDCPs are medica...
Read more
Valid
Publisher:
Austrian Standards International
Format:
Digital | 68 Pages
Language:
German | English
Optionally co-design standards:
This part of ISO 12417 specifies requirements for vascular device-drug combination products (VDDCPs) based upon current technical and medical knowledge. VDDCPs are medical devices with various clinical indications for use in the human vascular blood system. A VDDCP incorporates, as an integral part, substance(s) which, if used separately, can be considered to be a medicinal substance or product (drug substance, drug product) but the action of the medicinal substance is ancillary to that of the device and supports the primary mode of action (PMOA) of the device. With regard to safety, this part of ISO 12417 outlines requirements for intended performance, design attributes, materials, design evaluation, manufacturing, sterilization, packaging, and information supplied by the manufacturer. For implanted products, this International Standard should be considered as a supplement to ISO 14630, which specifies general requirements for the performance of non-active surgical implants. This International Standard should also be considered as a supplement to relevant device-specific standards, such as the ISO 25539-series specifying requirements for endovascular devices. Requirements listed in this part of ISO 12417 also address VDDCPs that are not permanent implants. Delivery systems or parts of the delivery system are included in the scope of this part of ISO 12417, if they comprise an integral component of the vascular device and if they are drug-covered (e.g. drugcovered balloon catheters and drug-covered guidewires). Devices whose PMOA is to provide a conduit for delivery of a drug, are excluded from the scope of this part of ISO 12417 (e.g. infusion catheters), unless they contain a drug component that is intended to have an ancillary action to the device part (e.g. antimicrobial coated infusion catheter). Procedures and devices used prior to and following the introduction of the VDDCP (e.g. balloon angioplasty devices) are excluded from the scope of this part of ISO 12417 if they do not affect the drugrelated aspects of the device. This part of ISO 12417 is not comprehensive with respect to the pharmacological evaluation of VDDCPs. Some information on the requirements of different national and regional authorities is given in Annex B. Absorbable components of VDDCPs (e.g. coatings) are addressed by this part of ISO 12417 in their connection with drug-related aspects of the device. Degradation and other time-dependent aspects of absorbable implants and coatings are not completely addressed by this part of ISO 12417. This part of ISO 12417 does not address issues associated with viable or non-viable biological materials such as tissues, cells, or proteins. This part of ISO 12417 does not address issues associated with active surgical implants (i.e. implants that require power not generated by the human body or gravity).
ÖNORM EN ISO 12417-1
2016 02 01
Cardiovascular implants and extracorporeal systems - Vascular device-drug combination products - Par...
Norm
Norm
ISO 10993-2:2006
Issue date : 2006 07 06
Biological evaluation of medical devices — Part 2: Animal welfare requirements
Norm
ISO 10993-7:2008
Issue date : 2008 10 13
Biological evaluation of medical devices — Part 7: Ethylene oxide sterilization residuals
Norm
ISO 11070:2014
Issue date : 2014 10 31
Sterile single-use intravascular introducers, dilators and guidewires
Norm
ISO 11607-1:2019
Issue date : 2019 01 31
Packaging for terminally sterilized medical devices — Part 1: Requirements for materials, sterile barrier systems and packaging systems
Norm
ISO 14630:2012
Issue date : 2012 11 28
Non-active surgical implants — General requirements
Norm
ISO 14937:2009
Issue date : 2009 10 14
Sterilization of health care products — General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices
Norm
ISO 14971:2007
Issue date : 2007 02 28
Medical devices — Application of risk management to medical devices (Corrected version 2007-09)
Norm
ISO 15223-1:2021
Issue date : 2021 07 06
Medical devices — Symbols to be used with information to be supplied by the manufacturer — Part 1: General requirements (Corrected version 2021-07)
Norm
ISO 25539-2:2020
Issue date : 2020 09 22
Cardiovascular implants — Endovascular devices — Part 2: Vascular stents
Norm
ISO 12417-1:2015
Issue date : 2015 09 27
Cardiovascular implants and extracorporeal systems — Vascular device-drug combination products — Part 1: General requirements