Please select and order
€109.76
excl. VAT
CONFIGURE NOW
Norm

ÖNORM EN ISO 11885

Issue date: 2009 11 01

Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES) (ISO 11885:2007)

This International Standard specifies a method for the determination of dissolved elements, elements bound to particles (¿particulate¿) and total content of elements in d...
Read more
Valid
Publisher:
Austrian Standards International
Format:
Digital | 33 Pages
Language:
German | English | Download GER/ENG
Optionally co-design standards:
This International Standard specifies a method for the determination of dissolved elements, elements bound to particles (¿particulate¿) and total content of elements in different types of water (e.g. ground, surface, raw, potable and waste water) for the following elements: aluminium, antimony, arsenic, barium, beryllium, bismuth, boron, cadmium, calcium, chromium, cobalt, copper, gallium, indium, iron, lead, lithium, magnesium, manganese, molybdenum, nickel, phosphorus, potassium, selenium, silicon, silver, sodium, strontium, sulfur, tin, titanium, tungsten, vanadium, zinc and zirconium. Taking into account the specific and additionally occurring interferences, these elements can also be determined in digests of water, sludges and sediments (for example, digests of water as specified in ISO 15587-1 or ISO 15587-2). The method is suitable for mass concentrations of particulate matter in waste water below 2 g/l. The scope of this method may be extended to other matrices or to higher amounts of particulate matter if it can be shown that additionally occurring interferences are considered and corrected for carefully. It is up to the user to demonstrate the fitness for purpose. Recommended wavelengths, limits of quantification and important spectral interferences for the selected elements are given in Table 1.
ÖNORM EN ISO 11885
2009 11 01
Water quality - Determination of selected elements by inductively coupled plasma optical emission sp...
Norm
ÖNORM EN ISO 11885
1998 03 01
Water quality - Determination of 33 elements by inductively coupled plasma atomic emission spectrosc...
Norm
ÖNORM M 6279
1991 10 01
Water analysis - Determination of 33 elements by inductively coupled plasma emission spectrometry (I...
Norm
Norm
ISO 3696:1987
Issue date : 1987 04 09
Water for analytical laboratory use — Specification and test methods
Norm
ISO 5667-1:2006
Issue date : 2006 12 14
Water quality — Sampling — Part 1: Guidance on the design of sampling programmes and sampling techniques
Norm
ISO 5667-3:2003
Issue date : 2003 12 09
Water quality — Sampling — Part 3: Guidance on the preservation and handling of water samples
Norm
ISO 7027:1999
Issue date : 1999 12 16
Water quality — Determination of turbidity
Norm
ISO 15587-1:2002
Issue date : 2002 02 28
Water quality — Digestion for the determination of selected elements in water — Part 1: Aqua regia digestion
Norm
ISO 15587-2:2002
Issue date : 2002 02 26
Water quality — Digestion for the determination of selected elements in water — Part 2: Nitric acid digestion
Norm
ISO 3696:1987
Issue date : 1987 04 09
Water for analytical laboratory use — Specification and test methods
Norm
ISO 5667-1:2020
Issue date : 2020 12 03
Water quality — Sampling — Part 1: Guidance on the design of sampling programmes and sampling techniques
Norm
ISO 5667-3:2018
Issue date : 2018 05 11
Water quality — Sampling — Part 3: Preservation and handling of water samples
Norm
ISO 15587-1:2002
Issue date : 2002 02 28
Water quality — Digestion for the determination of selected elements in water — Part 1: Aqua regia digestion
Norm
ISO 15587-2:2002
Issue date : 2002 02 26
Water quality — Digestion for the determination of selected elements in water — Part 2: Nitric acid digestion
Norm
ISO 11885:2007
Issue date : 2007 07 30
Water quality — Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)