Please select and order
€72.72
excl. VAT plus shipping costs
CONFIGURE NOW
Norm
ÖNORM EN 868-8
Issue date: 1999 10 01
Packaging materials and systems for medical devices which are to be sterilized - Part 8: Re-usable sterilization containers for steam sterilizers conforming to EN 285 - Requirements and test methods
This Part of the series of EN 868 provides examples of particular requirements and test methods for re-usable
containers for steam sterilization.
It introduces no addit...
Read more
Withdrawn
: 2009 09 15
Publisher:
Austrian Standards International
Format:
Digital | 18 Pages
Language:
German
| English
Currently valid:
Optionally co-design standards:
ICS
This Part of the series of EN 868 provides examples of particular requirements and test methods for re-usable
containers for steam sterilization.
It introduces no additional requirements to the general requirements of Part 1 but provides guidance based upon
various elements of former, relevant national standards.
As such, the particular requirements in 4.2 to 4.7 can be used to demonstrate compliance with one or more but not
ail of the requirements of Part 1.
The containers specified in this part of the standard are intended to be used as a packaging System during the
sterilization of medical devices in steam sterilizers conforming to EN 285 and the subsequent transportation and
storage of those devices.
NOTE 1 : When it is intended to use the containers in a steam sterilizer not conforming to EN 285 the sterilization
performance of the container in the specific sterilization cycle to be used is validated by the User. Other
attributes of the container are also reviewed for compatibility with the sterilizer cycle e. g. operating temperature.
ÖNORM EN 868-8
2019 02 01
Packaging for terminally sterilized medical devices - Part 8: Re-usable sterilization containers for...
Norm
ÖNORM EN 868-8
2009 09 15
Packaging for terminally sterilized medical devices - Part 8: Re-usable sterilization containers for...
Norm
ÖNORM EN 868-8
1999 10 01
Packaging materials and systems for medical devices which are to be sterilized - Part 8: Re-usable s...
Norm
↖
Norm
ISO 4582:2007
Issue date :
2007 07 23
Plastics — Determination of changes in colour and variations in properties after exposure to daylight under glass, natural weathering or laboratory light sources
Norm
ISO 4582:2017
Issue date :
2017 08 17
Plastics — Determination of changes in colour and variations in properties after exposure to glass-filtered solar radiation, natural weathering or laboratory radiation sources
Norm
ÖNORM EN 868-8
Issue date :
2009 09 15
Packaging for terminally sterilized medical devices - Part 8: Re-usable sterilization containers for steam sterilizers conforming to EN 285 - Requirements and test methods