Please select and order
€171.12
excl. VAT plus shipping costs
CONFIGURE NOW
Norm

ÖNORM EN 1634-1

Issue date: 2009 02 01

Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 1: Fire resistance tests for doors, shutters and openable windows

This Part of EN 1634 specifies a method for determining the fire resistance of doors, shutters and openable windows designed for installation within openings incorporate...
Read more
Withdrawn : 2014 02 15
This Part of EN 1634 specifies a method for determining the fire resistance of doors, shutters and openable windows designed for installation within openings incorporated in vertical separating elements, such as: - hinged or pivoted doors; - horizontally sliding and vertically sliding doors including articulated sliding doors and sectional doors; - sliding folding doors and shutters; - tilting doors; - rolling shutters; - openable windows; - openable fabric curtains. This European Standard is used in conjunction with EN 1363-1. Doors tested in accordance with this European Standard and classified in accordance with EN 13501-2 may be accepted for lift landing door applications as an alternative to EN 81-58. EN 81-58 represents a specific test for lift landing doors and results in an alternative classification which may not be suitable for some other purposes as defined in National Regulations. The testing of fire dampers is covered by EN 1366-2. The testing of closures for conveyor systems is covered by EN 1366-7. Further requirements are described in the relevant product standard and in the supporting standard EN 14600. This method may also be used to determine the fire resistance of non-loadbearing horizontally orientated doors, shutters and openable windows by analogy. However, these are not specifically addressed here and the field of direct application given in Clause 13 is not valid for such horizontally orientated products. By prior agreement with the test sponsor additional information may be gained for individual elements of building hardware. Based on the observations recorded during the test, the results may be presented in a separate report.
ÖNORM EN 1634-1
2018 05 01
Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elemen...
Norm
ÖNORM EN 1634-1
2016 06 01
Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elemen...
Norm
ÖNORM EN 1634-1
2014 02 15
Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elemen...
Norm
ÖNORM EN 1634-1
2009 02 01
Fire resistance and smoke control tests for door, shutter and openable window assemblies and element...
Norm
ÖNORM EN 1634-1
2007 02 01
Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elemen...
Norm
ÖNORM EN 1634-1
2000 10 01
Fire resistance tests for door and shutter assemblies - Part 1: Fire doors and shutters
Norm
Historie aufklappen
Norm
ÖNORM EN 1363-1
Issue date : 2012 09 01
Fire resistance tests - Part 1: General Requirements
Norm
ÖNORM EN 1363-2
Issue date : 2000 01 01
Fire resistance tests - Part 2: Alternative and additional procedures
Norm
ÖNORM EN ISO 13943
Issue date : 2011 01 15
Fire safety - Vocabulary (ISO 13943:2008)
Norm
ÖNORM EN 12519
Issue date : 2004 05 01
Windows and pedestrian doors - Terminology
Norm
ÖNORM EN 14600
Issue date : 2006 03 01
Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification
Norm
ÖNORM EN 13501-2
Issue date : 2010 02 15
Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
Norm
ÖNORM EN 1634-1
Issue date : 2014 02 15
Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable windows