Please select and order
€109.76
excl. VAT
CONFIGURE NOW
Norm

ÖNORM EN 15882-2

Issue date: 2015 05 15

Extended application of results from fire resistance tests for service installations - Part 2: Fire dampers

This European Standard provides guidance and rules to notified bodies (for fire dampers) to allow them to produce/validate an extended field of application report for fir...
Read more
Withdrawn : 2023 02 15
This European Standard provides guidance and rules to notified bodies (for fire dampers) to allow them to produce/validate an extended field of application report for fire dampers. This standard identifies the parameters that affect the fire resistance of dampers. It also identifies the factors that need to be considered when deciding whether, or by how much, the parameter can be extended when contemplating the fire resistance performance of an untested, or untestable variation in the construction. This European Standard explains the principles behind how a conclusion on the influence of specific parameters/constructional details relating to the relevant criteria (E,I,S) can be achieved. This European Standard does not cover dampers used for smoke control. This European Standard only applies to extended fields of application based on tests successfully undertaken to EN 1366-2. Only test reports that have a total test time where the criteria are fulfilled that is in excess of the required classification period by a margin of either 10 % or 12 min, whichever is the least, are to be considered. Each classification (E,I,S) is to be considered individually – consequently E (134 min achieved) may be extended, but EI (61 min achieved) may not be extended for a classification of EI60. Additionally, leakage determined during such tests is to be at least 10 % below the leakage limits for E, or for E-S, dependent on classification achieved, given in EN 13501-3 before the EXAP rules can be applied. The 10 % below the leakage limits is to be fulfilled for the extended period in addition to the classification period. By application of this European Standard, it should be possible to identify what specifications should be tested to maximize the field of application. Some information on test programmes is given for guidance purposes.
ÖNORM EN 15882-2
2023 02 15
Extended application of results from fire resistance tests for service installations - Part 2: Fire ...
Norm
ÖNORM EN 15882-2
2015 05 15
Extended application of results from fire resistance tests for service installations - Part 2: Fire ...
Norm
Norm
ISO 10294-4:2001
Issue date : 2001 03 29
Fire resistance tests — Fire dampers for air distribution systems — Part 4: Test of thermal release mechanism
Norm
ÖNORM EN 1363-1
Issue date : 2012 09 01
Fire resistance tests - Part 1: General Requirements
Norm
ÖNORM EN 1366-1
Issue date : 2014 11 15
Fire resistance tests for service installations - Part 1: Ventilation ducts
Norm
ÖNORM EN 1366-2
Issue date : 2015 09 01
Fire resistance tests for service installations - Part 2: Fire dampers
Norm
ÖNORM EN 13501-3
Issue date : 2009 12 01
Fire classification of construction products and building elements - Part 3: Classification using data from fire resistance tests on products and elements used in building service installations: fire resisting ducts and fire dampers
Norm
ÖNORM EN 15882-1
Issue date : 2012 02 01
Extended application of results from fire resistance tests for service installations - Part 1: Ducts
Norm
ISO 10294-4:2001
Issue date : 2001 03 29
Fire resistance tests — Fire dampers for air distribution systems — Part 4: Test of thermal release mechanism
Norm
ÖNORM EN 15882-2
Issue date : 2023 02 15
Extended application of results from fire resistance tests for service installations - Part 2: Fire dampers