Please select and order
€185.23
excl. VAT
CONFIGURE NOW
Norm

ÖNORM EN 15269-4

Issue date: 2022 11 15

Extended application of test results for fire resistance and/or smoke control for door, shutter and openable window assemblies, including their elements of building hardware - Part 4: Fire resistance of hinged and pivoted glass doorsets

This document covers hinged and pivoted doors, doorsets and door assemblies with glass based leaves. Throughout this document the term “doorset” will be used to cover doo...
Read more
Valid
This document covers hinged and pivoted doors, doorsets and door assemblies with glass based leaves. Throughout this document the term “doorset” will be used to cover doors, doorsets and door assemblies. It prescribes the methodology for extending the application of test results obtained from fire resistance test(s) conducted in accordance with EN 1634-1 and/or EN 1634-3 and/or EN 1191. Subject to the completion of the appropriate test or tests, the extended application may cover all or some of the following examples: - integrity (E), integrity & radiation (EW) or integrity & insulation (EI1 or EI2) classification; - ambient temperature smoke control (Sa) and medium temperature smoke control (S200) classifications; - ability to close and durability of self-closing (C0 - C5); - glazed elements; - side, transom or over panels; - items of building hardware; - decorative and protective finishes; - intumescent seals and non-intumescent (e.g. smoke, draught or acoustic) seals; - alternative supporting construction(s). This document does not cover horizontal doorsets and windows.