Please select and order
€203.49
excl. VAT
CONFIGURE NOW
Norm

ÖNORM EN 14212

Issue date: 2014 07 01

Ambient air - Standard method for the measurement of the concentration of sulphur dioxide by ultraviolet fluorescence (consolidated version)

This European Standard specifies a continuous measurement method for the determination of the concentration of sulphur dioxide present in ambient air based on the ultrav...
Read more
Valid
Publisher:
Austrian Standards International
Format:
Digital | 104 Pages
Language:
German | English | Download GER/ENG
Optionally co-design standards:
This European Standard specifies a continuous measurement method for the determination of the concentration of sulphur dioxide present in ambient air based on the ultraviolet fluorescence measuring principle. This standard describes the performance characteristics and sets the relevant minimum criteria required to select an appropriate ultraviolet fluorescence analyser by means of type approval tests. It also includes the evaluation of the suitability of an analyser for use in a specific fixed site so as to meet the data quality requirements as specified in Annex I of Directive 2008/50/EC and requirements during sampling, calibration and quality assurance for use. The method is applicable to the determination of the mass concentration of sulphur dioxide present in ambient air up to 1000 µg/m3. This concentration range represents the certification range for SO2 for the type approval test. The method covers the determination of ambient air concentrations of sulphur dioxide in zones classified as rural areas, urban-background areas and traffic-orientated locations and locations influenced by industrial sources. The results are expressed in µg/m3 (at 20 °C and 101,3 kPa). This standard contains information for different groups of users. Clauses 5 to 7 and Annexes C and D contain general information about the principles of sulphur dioxide measurement by ultraviolet fluorescence analyser and sampling equipment. Clause 8 and Annex E are specifically directed towards test houses and laboratories that perform type-approval testing of sulphur dioxide analysers. These sections contain information about: - Type-approval test conditions, test procedures and test requirements; - Analyser performance requirements; - Evaluation of the type-approval test results; - Evaluation of the uncertainty of the measurement results of the sulphur dioxide analyser based on the typeapproval test results. Clauses 9 to 11 and Annexes F and G are directed towards monitoring networks performing the practical measurements of sulphur dioxide in ambient air. These sections contain information about: - Initial installation of the analyser in the monitoring network and acceptance testing; - Ongoing quality assurance/quality control; - Calculation and reporting of measurement results; - Evaluation of the uncertainty of measurement results under practical monitoring conditions.
ÖNORM EN 14212
2014 07 01
Ambient air - Standard method for the measurement of the concentration of sulphur dioxide by ultravi...
Norm
ÖNORM EN 14212
2014 05 01
Ambient air - Standard method for the measurement of the concentration of sulphur dioxide by ultravi...
Norm
ÖNORM EN 14212
2005 10 01
Ambient air quality - Standard method for the measurement of the concentration of sulphur dioxide by...
Norm
ÖNORM M 5854
1999 06 01
Air analysis - Ambient air monitoring - Monitors for SO2 - Requirements and testing
Norm
ÖNORM M 5854
1990 10 01
Air analysis; ambient air monitoring; requirements for SO2-measuring equipement; marking of conformi...
Norm
Historie aufklappen
Norm
ÖNORM EN ISO 14956
Issue date : 2003 01 01
Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002)
Norm
ÖNORM EN ISO 6143
Issue date : 2006 10 01
Gas analysis - Comparison methods for determining and checking the composition of calibration gas mixtures (ISO 6143:2001)
Norm
ÖNORM EN ISO 6144
Issue date : 2006 10 01
Gas analysis - Preparation of calibration gas mixtures - Static volumetric method (ISO 6144:2003)
Norm
ÖNORM EN ISO 6142
Issue date : 2006 10 01
Gas analysis - Preparation of calibration gas mixtures - Gravimetric method (ISO 6142:2001)
Norm
ÖNORM EN ISO 6145-10
Issue date : 2008 11 01
Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 10: Permeation method (ISO 6145-10:2002)
Norm
ÖNORM EN ISO 6145-6
Issue date : 2008 11 01
Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 6: Critical orifices (ISO 6145-6:2003)
Norm
ÖNORM EN 15267-1
Issue date : 2009 07 01
Air quality - Certification of automated measuring systems - Part 1: General principles
Norm
ÖNORM EN 15267-2
Issue date : 2009 07 01
Air quality - Certification of automated measuring systems - Part 2: Initial assessment of the AMS manufacturer's quality management system and post certification surveillance for the manufacturing process
Norm
ÖNORM EN ISO 6145-7
Issue date : 2011 03 15
Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 7: Thermal mass-flow controllers (ISO 6145-7:2009)