Please select and order
€160.20
excl. VAT plus shipping costs
CONFIGURE NOW
Norm
ÖNORM EN 13501-2
Issue date: 2004 01 01
Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services
This Part of this European Standard specifies the procedure for classification of construction products and building
elements using data from fire resistance and smoke l...
Read more
Withdrawn
: 2008 01 01
Publisher:
Austrian Standards International
Format:
Digital | 71 Pages
Language:
German
| English
Currently valid:
Optionally co-design standards:
This Part of this European Standard specifies the procedure for classification of construction products and building
elements using data from fire resistance and smoke leakage tests which are within the direct field of application of
the relevant test method. This part of this European Standard currently cannot be applied to classify curtain walling
for resistance to fire. Classification on the basis of extended application is outside the scope of this standard. For
extended application, however, the same classes are used as specified in this standard.
This standard deals with:
a) Loadbearing elements without a fire separating function
walls
floors
roofs
beams
columns
balconies
walkways
stairs
b) Loadbearing elements with a fire separating function, with or without glazing, services and fixtures
walls
floors
roofs
raised floors
c) Products and systems for protecting elements or parts of the works
ceilings with no independent fire resistance
fire protective coatings, claddings and screens
d) Non-loadbearing elements or parts of works, with or without glazing, services and fixtures
partitions
facades (curtain walls) and external walls
ceilings with independent fire resistance
fire doors and shutters and their closing devices
smoke control doors
conveyor systems and their closures
penetration seals
linear joint seals
service ducts and shafts
chimneys
e) Wall and ceiling coverings with fire protection ability
f) Lift landing doors which are tested to prEN 81-8 are excluded from this standard. Lift landing doors which are
tested to EN 1634-1 are classified in accordance with 7.5.5.
Relevant test methods which have been prepared for these elements are listed in clause 2.
ÖNORM EN 13501-2
2023 09 01
Fire classification of construction products and building elements - Part 2: Classification using da...
Norm
ÖNORM EN 13501-2
2016 11 01
Fire classification of construction products and building elements - Part 2: Classification using da...
Norm
ÖNORM EN 13501-2
2010 02 15
Fire classification of construction products and building elements - Part 2: Classification using da...
Norm
ÖNORM EN 13501-2
2008 01 01
Fire classification of construction products and building elements - Part 2: Classification using da...
Norm
ÖNORM EN 13501-2
2004 01 01
Fire classification of construction products and building elements - Part 2: Classification using da...
Norm
↖
ÖNORM B 3800-2
1997 03 01
Behaviour of building materials and components in fire - Components: definitions, requirements, test...
Norm
ÖNORM B 3800-3
1995 12 01
Behaviour of building materials and components in fire - Special components: Definitions, requiremen...
Norm
ÖNORM B 3800-3
1983 10 01
Behaviour of building materials and components in fire; special components: definitions, requirement...
Norm
ÖNORM B 3800-2
1982 12 01
Behaviour of building materials and components in fire; components: definitions, requirements, tests...
Norm
ÖNORM B 3800-3
1973 12 01
Behaviour of building materials and components in fire; special components: definitions, requirement...
Norm
ÖNORM B 3800-2
1972 01 01
Behaviour of building materials and structures in fire; definitions, requirements, tests of structur...
Norm
Norm
ÖNORM EN 13216-1
Issue date :
2004 11 01
Chimneys - Test methods for system chimneys - Part 1: General test methods
Norm
ÖNORM EN 1363-2
Issue date :
2000 01 01
Fire resistance tests - Part 2: Alternative and additional procedures
Norm
ÖNORM EN 1364-1
Issue date :
2000 04 01
Fire resistance tests for non-loadbearing elements - Part 1: Walls
Norm
ÖNORM EN 1364-2
Issue date :
2000 04 01
Fire resistance tests for non-loadbearing elements - Part 2: Ceilings
Norm
ÖNORM EN 1365-1
Issue date :
2000 04 01
Fire resistance tests for loadbearing elements - Part 1: Walls
Norm
ÖNORM EN 1365-2
Issue date :
2000 06 01
Fire resistance tests for loadbearing elements - Part 2: Floors and roofs
Norm
ÖNORM EN 1365-3
Issue date :
2000 06 01
Fire resistance tests for loadbearing elements - Part 3: Beams
Norm
ÖNORM EN 1365-4
Issue date :
2000 04 01
Fire resistance tests for loadbearing elements - Part 4: Columns
Norm
ÖNORM EN 1365-5
Issue date :
2005 01 01
Fire resistance tests for loadbearing elements - Part 5: Balconies and walkways
Norm
ÖNORM EN 1365-6
Issue date :
2005 01 01
Fire resistance tests for loadbearing elements - Part 6: Stairs
Norm
ÖNORM EN 1366-3
Issue date :
2004 12 01
Fire resistance tests for service installations - Part 3: Penetration seals
Norm
ÖNORM EN 1366-3
Issue date :
2006 11 01
Fire resistance tests for service installations - Part 3: Penetration seals
Norm
ÖNORM EN 1366-4
Issue date :
2006 07 01
Fire resistance tests for service installations - Part 4: Linear joint seals
Norm
ÖNORM EN 1366-5
Issue date :
2003 11 01
Fire resistance tests for service installations - Part 5: Service ducts and shafts
Norm
ÖNORM EN 1366-5
Issue date :
2007 12 01
Fire resistance tests for service installations - Part 5: Service ducts and shafts
Norm
ÖNORM EN 1366-6
Issue date :
2005 01 01
Fire resistance tests for service installations - Part 6: Raised access and hollow core floors
Norm
ÖNORM EN 1366-7
Issue date :
2004 09 01
Fire resistance tests for service installations - Part 7: Conveyor systems and their closures
Norm
ÖNORM EN 14600
Issue date :
2006 03 01
Doorsets and openable windows with fire resisting and/or smoke control characteristics - Requirements and classification
Norm
ÖNORM EN 1634-1
Issue date :
2009 02 01
Fire resistance and smoke control tests for door, shutter and openable window assemblies and elements of building hardware - Part 1: Fire resistance tests for doors, shutters and openable windows
Norm
ÖNORM EN 1634-3
Issue date :
2007 02 01
Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 3: Smoke control test for door and shutter assemblies (consolidated version)
Norm
ÖNORM EN 81-58
Issue date :
2003 11 01
Safety rules for the construction and installation of lifts - Examination and tests - Part 58: Landing doors fire resistance test
Norm
ÖNORM EN 13501-2
Issue date :
2008 01 01
Fire classification of construction products and building elements - Part 2: Classification using data from fire resistance tests, excluding ventilation services