ÖNORM EN 12309-2

Issue date: 2000 04 01

Gas-fired absorption and adsorption air-conditioning and/or heat pump appliances with a net heat input not exceeding 70 kW - Part 2: Rational use of energy

This European standard specifies the requirements and methods of test for the rational use of energy of gas-fired absorption and adsorption air conditioning and/or heat p...
Read more
Withdrawn : 2016 01 15
This European standard specifies the requirements and methods of test for the rational use of energy of gas-fired absorption and adsorption air conditioning and/or heat pump appliances having a net heat input not exceeding 70 kW, hereafter referred to as "appliances". This standard applies to appliances having flue systems of Type B , B , B , B , B , B , 12 12BS 13 13BS 14 22 B , C , C , C and C , and to appliances designed for outdoor installations. This standard only applies to appliances having: integral burners under the control of fully automatic burner control systems; closed system refrigerant circuits in which the refrigerant does not come into direct contact with the fluid to be cooled or heated; mechanical means to assist transportation of the combustion air and/or the flue gases. Appliances covered by this standard include one or a combination of the following: gas-fired absorption air conditioner; gas-fired adsorption air conditioner; gas-fired absorption heat pump; gas-fired adsorption heat pump. The above appliances can have one or more primary or secondary functions (see 3.5 and 3.6) and this standard applies to all such functions providing that the function concerned is dependent on circulation of fluid within the absorption, or adsorption, refrigerant circuit. NOTE Any appliance function that is not dependent on circulation of the fluid within the absorption, or adsorption, refrigerant circuit should be assessed separately. This standard does not apply to appliances fitted with more than one flue outlet. This standard is applicable to appliances that are intended to be type tested. Requirements for appliances that are not type tested would need to be subject to further consideration.
ÖNORM EN 12309-1
2023 10 15
Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW -...
Norm
ÖNORM EN 12309-4
2016 01 15
Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW -...
Norm
ÖNORM EN 12309-3
2016 01 15
Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW -...
Norm
ÖNORM EN 12309-6
2016 01 15
Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW -...
Norm
ÖNORM EN 12309-5
2016 01 15
Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW -...
Norm
ÖNORM EN 12309-7
2016 01 15
Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW -...
Norm
ÖNORM EN 12309-1
2016 01 15
Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW -...
Norm
ÖNORM EN 12309-2
2000 04 01
Gas-fired absorption and adsorption air-conditioning and/or heat pump appliances with a net heat inp...
Norm
Historie aufklappen
Norm
ÖNORM EN 12309-1
Issue date : 1999 10 01
Gas-fired absorption and adsorption air-conditioning and/or heat pump appliances with a net heat input not exceeding 70 kW - Part 1: Safety
Norm
ISO 5151:1994
Issue date : 1994 12 22
Non-ducted air conditioners and heat pumps — Testing and rating for performance
Norm
ÖNORM EN 12309-1
Issue date : 2016 01 15
Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 1: Terms and definitions
Norm
ÖNORM EN 12309-3
Issue date : 2016 01 15
Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 3: Test conditions
Norm
ÖNORM EN 12309-4
Issue date : 2016 01 15
Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 4: Test methods
Norm
ÖNORM EN 12309-5
Issue date : 2016 01 15
Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 5: Requirements
Norm
ÖNORM EN 12309-6
Issue date : 2016 01 15
Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 6: Calculation of seasonal performances
Norm
ÖNORM EN 12309-7
Issue date : 2016 01 15
Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 7: Specific provisions for hybrid appliances