Please select and order
€109.76
excl. VAT
CONFIGURE NOW
Vornorm

ÖNORM CEN/TS 14816

Issue date: 2009 02 01

Fixed firefighting systems - Water spray systems - Design, installation and maintenance

This Technical Specification specifies requirements and gives recommendations for the design, installation and maintenance of fixed deluge water spray systems internal a...
Read more
Valid
Publisher:
Austrian Standards International
Format:
Digital | 33 Pages
Language:
German | English | Download GER/ENG
Optionally co-design standards:
This Technical Specification specifies requirements and gives recommendations for the design, installation and maintenance of fixed deluge water spray systems internal and external to buildings and industrial plant and other premises on land. This Technical Specification covers only the use of the types of sprinklers and sprayers specified in EN 12259-1. The requirements and recommendations of this Technical Specification are also applicable to any addition, extension, repair or other modification to a water spray system. This Technical Specification does not deal with sprinkler systems. It covers the hazards, provision of water supplies, components to be used, installation and testing of the system, maintenance, and the extension of existing systems, and identifies construction details of buildings which are necessary for the satisfactory performance of water spray systems complying with this Technical Specification. The general principles may well apply to other uses (e.g. maritime use), for these other uses additional considerations will almost certainly have to be taken into account. For water spray systems covered by this Technical Specification the authority shall be consulted.
ÖNORM CEN/TS 14816
2009 02 01
Fixed firefighting systems - Water spray systems - Design, installation and maintenance
Vornorm
ÖNORM CEN/TS 14816
2008 06 15
Fixed firefighting systems - Water spray systems - Design, installation and maintenance
Vornorm Entwurf
Norm
ÖNORM EN 12259-2
Issue date : 2006 02 01
Fixed firefighting systems - Components for sprinkler and water spray systems - Part 2: Wet alarm valve assemblies (consolidated version)
Norm
ÖNORM EN 12259-3
Issue date : 2006 02 01
Fixed firefighting systems - Components for sprinkler and water spray systems - Part 3: Dry alarm valve assemblies (consolidated version)
Norm
ÖNORM EN 12259-9
Issue date : 2004 12 01
Fixed firefighting systems - Components for sprinkler and water spray systems - Part 9: Deluge valve assemblies
Norm
ÖNORM EN 12845
Issue date : 2004 01 01
Fixed firefighting systems - Automatic sprinkler systems - Design, installation and maintenance
Norm
ÖNORM EN 54-1
Issue date : 1996 06 01
Fire detection and fire alarm systems - Part 1: Introduction
Norm
ÖNORM EN 54-1
Issue date : 2008 12 01
Fire detection and fire alarm systems - Part 1: Introduction
Norm
ÖNORM EN 54-10
Issue date : 2006 02 01
Fire detection and fire alarm systems - Part 10: Flame detectors - Point detectors (consolidated version)
Norm
ÖNORM EN 54-11
Issue date : 2006 02 01
Fire detection and fire alarm systems - Part 11: Manual call points (consolidated version)
Norm
ÖNORM EN 54-3
Issue date : 2006 09 01
Fire detection and fire alarm systems - Part 3: Fire alarm devices - Sounders (consolidated version)
Norm
ÖNORM EN 54-4
Issue date : 2006 10 01
Fire detection and fire alarm systems - Part 4: Power supply equipment (consolidated version)
Norm
ÖNORM EN 54-5
Issue date : 2001 04 01
Fire detection and fire alarm systems - Part 5: Heat detectors - Point detectors