STANDARD

Current

ÖNORM EN ISO 14146

Issue date: 2025 02 15

Radiological protection - Criteria and performance limits for the periodic evaluation of dosimetry services for external radiation (ISO 14146:2024)

This document specifies the dosimetric and organizational criteria and the test procedures to be used for the periodic verification of the performance of dosimetry services supplying personal and/or area, i.e. workplace and/or environmental, dosemeters used for individual (personal) and/or area, i.e. workplace and/or environmental monitoring. NOTE            The quality of a supplier of a dosimetry service depends on both the characteristics of the approved (type‑tested) dosimetry system and the training and experience of the staff, together with the calibration procedures and quality assurance programmes. The performance evaluation according to this document can be carried out by a dosimetry service to demonstrate the fulfilment of specified performance requirements. The irradiation qualities used in this document are representative for exposure situations that are expected or mimic workplace fields from the radiological activities being monitored using the dosemeters from the services. This document applies to personal and area dosemeters for the assessment of external photon radiation with a fluence-weighted mean energy between 8 keV and 10 MeV, beta radiation with a fluence-weighted mean energy between 60 keV and 1,2 MeV, and neutron radiation with a fluence-weighted mean energy between 25,3 meV, i.e. thermal neutrons with a Maxwellian energy distribution with kT = 25,3 meV, and 200 MeV. It covers all types of personal and area dosemeters needing laboratory processing (e.g. thermoluminescent, optically stimulated luminescence, radiophotoluminescent, track detectors or photographic-film dosemeters) and involving continuous measurements or measurements repeated regularly at fixed time intervals (e.g. several weeks, one month). Active direct reading as well as semi-passive or hybrid dosemeters, such as direct ion storage (DIS) or silicon photomultiplier (SiPM) dosemeters, for dose measurement, can also be treated according to this document. Then, they are treated as if they were passive, i.e. the dosimetry service reads their indicated values and reports them to the evaluation organization. In this document, the corrected indicated (corrected indication) value is the one given by the dosimetry systems as the final result of the evaluation algorithm (for example display of the software, printout) in units of dose equivalent (Sv). Environmental dosemeters usually indicate the quantity H*(10) but they can, in addition or alternatively, indicate the quantity H'(3), H'(0,07), air kerma, Ka, or absorbed dose, D. All these dosemeters can also be treated according to this document. If Ka or D is indicated (in Gy) the dose values in this document stated in Sv shall then be interpreted as equivalent values in Gy.

General information on ÖNORM EN ISO 14146

Format
Paper | 26 Pages
Language
German | English | Download GER/ENG
Publisher
Austrian Standards International

Timeline

An overview of the development of ÖNORM EN ISO 14146 from 2021 til today.

Frequently Asked Questions about ÖNORM EN ISO 14146

When you purchase a standard from the Austrian Standards webshop (e.g. ÖNORM, ISO), a single-user licence is included as standard. This entitles a single person to use the standard. A multi-user licence is required if several employees need access. It enables company-wide, legally compliant use and sharing of standards.

Find out more about the benefits of multi-user licences

Standardization thrives on expertise and participation. Anyone interested can play an active role in its further development – for example, by joining the relevant committee or a working group. In this way, you can help shape the content and contribute to advancing the state of the art.

Find out more about getting involved in standardization

If you have an extensive portfolio of standards, we recommend using a professional standards management tool. With effects 2.0, you can manage your standards centrally and efficiently. You can optimise your procurement processes and benefit from an integrated information and subscription service. This ensures you are always up to date and never miss any relevant developments.

Find out more about the benefits of effects 2.0

Normative References

Here you will find an extract of the normative references. Please refer to the document itself for the full list.

Dokumentnummer Titel Ausgabedatum Art Link
Dokumentnummer
ISO 12749-2:2013
Titel
Nuclear energy, nuclear technologies, and radiological protection — Vocabulary — Part 2: Radiological protection
Ausgabedatum
2013 09 13
Art
Standard
Dokumentnummer
ISO 12789-1:2008
Titel
Reference radiation fields — Simulated workplace neutron fields — Part 1: Characteristics and methods of production
Ausgabedatum
2008 03 04
Art
Standard
Dokumentnummer
ISO 12789-2:2008
Titel
Reference radiation fields — Simulated workplace neutron fields — Part 2: Calibration fundamentals related to the basic quantities
Ausgabedatum
2008 03 04
Art
Standard
Dokumentnummer
ISO 29661:2012
Titel
Reference radiation fields for radiation protection — Definitions and fundamental concepts
Ausgabedatum
2012 08 30
Art
Standard
Dokumentnummer
ISO 4037-1:2019
Titel
Radiological protection — X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy — Part 1: Radiation characteristics and production methods
Ausgabedatum
2019 01 18
Art
Standard
Dokumentnummer
ISO 4037-2:2019
Titel
Radiological protection — X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy — Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV (Corrected version 2019-03)
Ausgabedatum
2019 01 18
Art
Standard
Dokumentnummer
ISO 4037-3:2019
Titel
Radiological protection — X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy — Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence
Ausgabedatum
2019 01 30
Art
Standard
Dokumentnummer
ISO 6980-1:2006
Titel
Nuclear energy — Reference beta-particle radiation — Part 1: Methods of production
Ausgabedatum
2006 08 07
Art
Standard
Dokumentnummer
ISO 6980-2:2004
Titel
Nuclear energy — Reference beta-particle radiation — Part 2: Calibration fundamentals related to basic quantities characterizing the radiation field
Ausgabedatum
2004 10 06
Art
Standard
Dokumentnummer
ISO 6980-3:2006
Titel
Nuclear energy — Reference beta-particle radiation — Part 3: Calibration of area and personal dosemeters and the determination of their response as a function of beta radiation energy and angle of incidence
Ausgabedatum
2006 09 27
Art
Standard
Dokumentnummer
ISO 8529-1:2001
Titel
Reference neutron radiations — Part 1: Characteristics and methods of production
Ausgabedatum
2001 02 01
Art
Standard
Dokumentnummer
ISO 8529-2:2000
Titel
Reference neutron radiations — Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field
Ausgabedatum
2000 08 24
Art
Standard
Dokumentnummer
ISO 8529-3:1998
Titel
Reference neutron radiations — Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence
Ausgabedatum
1998 12 03
Art
Standard
Dokumentnummer
ISO/IEC 17025:2017
Titel
General requirements for the competence of testing and calibration laboratories (Corrected version 2017-11)
Ausgabedatum
2017 11 29
Art
Standard
Dokumentnummer
ISO/IEC Guide 98-3:2008
Titel
Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) (Corrected version 2010-11)
Ausgabedatum
2008 09 30
Art
Technische Regel
Dokumentnummer
ISO/TS 18090-1:2015
Titel
Radiological protection — Characteristics of reference pulsed radiation — Part 1: Photon radiation
Ausgabedatum
2015 07 21
Art
Technische Regel

Recently Viewed

ÖNORM EN ISO 18415

Cosmetics - Microbiology - Detection of specified and non-specified microorganisms (ISO 18415:2017 + Amd 1:2022) (condolidated version)

OIB Richtlinie - Begriffsbestimmungen

ÖNORM EN 13721

Furniture - Assessment of the surface reflectance
€178.08
excl. USt.
€195.89
incl. 10% USt.
Standard
ÖNORM EN ISO 14146 - Radiological protection - Criteria and performance limits for the periodic evaluation of dosimetry services for external radiation (ISO 14146:2024)

Customize and purchase single-user license

€178.08
excl. USt.
€195.89
incl. 10% USt.
Free delivery

Subscribe to standards

Your shopping cart is empty

Regarding the newly released ISO 9001, we recommend:

Standard
ÖNORM EN ISO 9001 - Quality management systems - Requirements (ISO 9001:2026)
View details
Seminar [Live-Online]
€749.00
excl. USt.
€898.80
incl. 20% USt.
View details
Seminar [Hybrid]
€675.00
excl. USt.
€810.00
incl. 20% USt.
View details
€49.00
excl. USt.
€58.80
incl. 20% USt.
View details
€2,419.00
excl. USt.
€2,902.80
incl. 20% USt.
View details