Characterisation of waste - Leaching - Compliance test for leaching of granular waste materials and sludges - Part 3: Two stage batch test at a liquid to solid ratio of 2 l/kg and 8 l/kg for materials with high solid content and with particle size below 4 mm (without or with size reduction)

This part of four European Standards specifies a compliance test providing information on leaching of granular wastes and sludges under the experimental conditions specified hereafter, and particularly a liquid to solid ratio of 2 l/kg dry matter in a first step and subsequently of 8 l/kg dry matter in a second step. It applies to waste which has a particle size below 4 mm without or with size reduction (as specified in 4.3.2) This European Standard has been developed to investigate mainly inorganic constituents from wastes. It does not take into account the particular characteristics of non-polar organic constituents nor the consequences of microbiological processes in organic degradable wastes. The test procedure specified in this European Standard produces eluates which shall subsequently be characterised physically and chemically according to appropriate standard methods. This procedure is only applicable to waste material and sludges having a high solid content : the dry matter content ratio shall be at least higher than 33%. In addition, the necessary quantity of eluate in each step shall be obtained to perform the physical and chemical characterisation of the eluate. Furthermore, the minimum dry matter content ratio shall be high enough to allow a sufficient mixing of the leachant and the test portion. NOTE 1 This procedure cannot be applicable to materials with a water content or such a water affinity that a good mixing of the solid with the predetermined quantity of liquid is not achievable. NOTE 2 This procedure cannot be applicable to materials reacting with the leachant, leading, for example, to excessive gas emission, a solidifying effect or an excessive heat release. NOTE 3 By crushing the material, new surfaces are exposed which may lead to a change in leaching properties. NOTE 4 In relation with the minimum dry matter content ratio required for obtaining enough eluate in the first st (...abbreviated)

General information on ÖNORM EN 12457-3

Format
Digital | 32 Pages
Language
German | English | Download GER/ENG
Publisher
Austrian Standards International

Timeline

An overview of the development of ÖNORM EN 12457-3 from 2003 til today.

Frequently Asked Questions about ÖNORM EN 12457-3

When you purchase a standard from the Austrian Standards webshop (e.g. ÖNORM, ISO), a single-user licence is included as standard. This entitles a single person to use the standard. A multi-user licence is required if several employees need access. It enables company-wide, legally compliant use and sharing of standards.

Find out more about the benefits of multi-user licences

Standardization thrives on expertise and participation. Anyone interested can play an active role in its further development – for example, by joining the relevant committee or a working group. In this way, you can help shape the content and contribute to advancing the state of the art.

Find out more about getting involved in standardization

If you have an extensive portfolio of standards, we recommend using a professional standards management tool. With effects 2.0, you can manage your standards centrally and efficiently. You can optimise your procurement processes and benefit from an integrated information and subscription service. This ensures you are always up to date and never miss any relevant developments.

Find out more about the benefits of effects 2.0

Normative References

Here you will find an extract of the normative references. Please refer to the document itself for the full list.

Dokumentnummer Titel Ausgabedatum Art Link
Dokumentnummer
ISO 11465:1993
Titel
Soil quality — Determination of dry matter and water content on a mass basis — Gravimetric method
Ausgabedatum
1993 12 09
Art
Standard
Dokumentnummer
ISO 5725-5:1998
Titel
Accuracy (trueness and precision) of measurement methods and results — Part 5: Alternative methods for the determination of the precision of a standard measurement method
Ausgabedatum
1998 07 23
Art
Standard

Recently Viewed

ÖNORM EN ISO 12004-1

Metallic materials - Sheet and strip - Determination of forming-limit curves - Part 1: Measurement and application of forming-limit diagrams in the press shop (ISO 12004-1:2008)

ÖNORM ETS 300925

Digital cellular telecommunications system (Phase 2+) - Voice Group Call Service (VGCS) - Stage 1 (GSM 02.68 version 5.1.3)

ÖNORM EN ISO 407

Small medical gas cylinders - Pin-index yoke-type valve connections (ISO 407:2021)
€106.23
excl. USt.
€116.85
incl. 10% USt.
Standard
ÖNORM EN 12457-3 - Characterisation of waste - Leaching - Compliance test for leaching of granular waste materials and sludges - Part 3: Two stage batch test at a liquid to solid ratio of 2 l/kg and 8 l/kg for materials with high solid content and with particle size below 4 mm (without or with size reduction)

Customize and purchase single-user license

€106.23
excl. USt.
€116.85
incl. 10% USt.

Subscribe to standards

Your shopping cart is empty

Regarding the newly released ISO 9001, we recommend:

Standard
ÖNORM EN ISO 9001 - Quality management systems - Requirements (ISO 9001:2026)
View details
Seminar [Live-Online]
€749.00
excl. USt.
€898.80
incl. 20% USt.
View details
Seminar [Hybrid]
€675.00
excl. USt.
€810.00
incl. 20% USt.
View details
€49.00
excl. USt.
€58.80
incl. 20% USt.
View details
€2,419.00
excl. USt.
€2,902.80
incl. 20% USt.
View details