ÖNORM EN ISO 10304-1

Issue date: 1995 07 01

Water quality - Determination of dissolved fluoride, chloride, nitrite, orthophosphate, bromide, nitrate and sulfate ions, using liquid chromatography of ions - ......(abbreviated)

This part of ISO 10304 specifies a method for the determination of fluoride, chloride, nitrite, orthophosphate, bromide, nitrate and sulfate in water with low contamination (e.g. drinking water, rain water, ground water and surface water) in the following ranges: Fluoride (F): 0,Ol mg/1 to IO mg/l Chloride (Cl): 0,l mg/l to 50 mg/l Nitrite (NO,): 0,05 mg/l to 20 mg/l Orthophosphate (PO,): 0,l mg/l to 20 mg/1 Bromide (Br): 0,05 mg/l to 20 mg/l Nitrate (NO,): 0,l mg/l to 50 mg/1 Sulfate (SO,): 0,l mg/1 to 100 mg/1 NOTE 1 Anion Symbols are used without charges throughout the text. In certain cases, the range of application may be changed by variations in the working conditions (e.g. Sample volume, dilution, separating columns, preconcentration techniques, sensitivity ranges of detectors, etc.). 1.2 Interferences 1.2.1 Some organic acids, such as malonic acid, malcic acid and malic acid, may interfere in the determination of inorganic anions if they are present in high concentrations. 1.2.2 The determination of fluoride in particular is subject to interference by formic acid, acetic acid and carbonate, even at low concentrations. 1.2.3 Cross sensitivity (lack of resolution) may occur in the case of large differentes in concentration between the anions determined (F, Cl, NO,, PO,, Br, NO,, SO,). 1.2.4 The bromide and Phosphate anions do not interfere in the working range specified, unless otherwise stated. 1.2.5 In a buffered eluent (e.g. carbonate/hydrogencarbonate), the determination will not be influenced by the Sample pH in the range of pH 2 to pH 9. 1.2.6 The concentration ratios given in table 1 were checked experimentally for various representative conditions. No interferences could be observed when 50 ~1 of Sample volume was used for the chromatographic analysis. 1.2.7 The information in 1.2.4 to 1.2.6 is valid only as long as the quality requirements of the separating (...abbreviated)

General information on ÖNORM EN ISO 10304-1

Format
Digital | 22 Pages
Language
German | English | Download GER/ENG
Publisher
Austrian Standards International

Timeline

An overview of the development of ÖNORM EN ISO 10304-1 from 1990 til today.

Frequently Asked Questions about ÖNORM EN ISO 10304-1

This standard is cited in Austrian laws or regulations and may therefore have binding effect. The citation demonstrates that the standard is used as a recognised basis for meeting legal requirements.

ÖNORM EN ISO 10304-1 is cited in the following Austrian laws or regulations:

When you purchase a standard from the Austrian Standards webshop (e.g. ÖNORM, ISO), a single-user licence is included as standard. This entitles a single person to use the standard. A multi-user licence is required if several employees need access. It enables company-wide, legally compliant use and sharing of standards.

Find out more about the benefits of multi-user licences

Standardization thrives on expertise and participation. Anyone interested can play an active role in its further development – for example, by joining the relevant committee or a working group. In this way, you can help shape the content and contribute to advancing the state of the art.

Find out more about getting involved in standardization

If you have an extensive portfolio of standards, we recommend using a professional standards management tool. With effects 2.0, you can manage your standards centrally and efficiently. You can optimise your procurement processes and benefit from an integrated information and subscription service. This ensures you are always up to date and never miss any relevant developments.

Find out more about the benefits of effects 2.0

Normative References

Here you will find an extract of the normative references. Please refer to the document itself for the full list.

Dokumentnummer Titel Ausgabedatum Art Link
Dokumentnummer
ISO 5667-1:2020
Titel
Water quality — Sampling — Part 1: Guidance on the design of sampling programmes and sampling techniques
Ausgabedatum
2020 12 03
Art
Standard
Dokumentnummer
ISO 5667-2:1991
Titel
Water quality — Sampling — Part 2: Guidance on sampling techniques
Ausgabedatum
1991 07 18
Art
Standard
Dokumentnummer
ISO 5667-3:1994
Titel
Water quality — Sampling — Part 3: Guidance on the preservation and handling of samples
Ausgabedatum
1994 07 28
Art
Standard
Dokumentnummer
ISO 8466-1:1990
Titel
Water quality — Calibration and evaluation of analytical methods and estimation of performance characteristics — Part 1: Statistical evaluation of the linear calibration function
Ausgabedatum
1990 03 01
Art
Standard

Recently Viewed

ÖNORM EN 9300-121

Aerospace series - LOTAR - LOng Term Archiving and Retrieval of digital technical product documentation such as 3D, CAD and PDM data - Part 121: Semantic representation of CAD 3D Explicit Geometry with Product and Manufacturing Information

ÖVE HD 516 S1/A4

Guide to use of low voltage harmonized cables

ÖNORM EN 16603-50-13

Space engineering - Interface and communication protocol for MIL-STD-1553B data bus onboard spacecraft
€106.23
excl. USt.
€116.85
incl. 10% USt.
Standard
ÖNORM EN ISO 10304-1 - Water quality - Determination of dissolved fluoride, chloride, nitrite, orthophosphate, bromide, nitrate and sulfate ions, using liquid chromatography of ions - ......(abbreviated)

Customize and purchase single-user license

€106.23
excl. USt.
€116.85
incl. 10% USt.

Subscribe to standards

Your shopping cart is empty

Regarding the newly released ISO 9001, we recommend:

Standard
ÖNORM EN ISO 9001 - Quality management systems - Requirements (ISO 9001:2026)
View details
Seminar [Live-Online]
€749.00
excl. USt.
€898.80
incl. 20% USt.
View details
Seminar [Hybrid]
€675.00
excl. USt.
€810.00
incl. 20% USt.
View details
€49.00
excl. USt.
€58.80
incl. 20% USt.
View details
€2,419.00
excl. USt.
€2,902.80
incl. 20% USt.
View details