Jetzt auswählen und bestellen
232,70 €
exkl. USt.
Konfigurieren
Norm

OVE EN 62423

Ausgabedatum: 2022 04 01

Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses (english version)

The scope of IEC 61008-1 and IEC 61009-1 applies with the following additions. This standard specifies requirements and tests for Type F and Type B RCDs (Residual Curren...
Weiterlesen
ZURÜCKZIEHUNG AM : 2025 07 01
The scope of IEC 61008-1 and IEC 61009-1 applies with the following additions. This standard specifies requirements and tests for Type F and Type B RCDs (Residual Current Devices). Requirements and tests given in this standard are in addition to the requirements of Type A residual current devices. This standard can only be used together with IEC 61008-1 and IEC 61009-1. Type F RCCBs (Residual Current Circuit Breaker) and Type F RCBOs (Residual current Circuit Breaker with Overcurrent protection) with rated frequency 50 Hz or 60 Hz are intended for installations when frequency inverters are supplied between phase and neutral or phase and earthed middle conductor and are able to provide protection in case of alternating residual sinusoidal at the rated frequency, pulsating direct residual currents and composite residual currents that may occur. Type B RCCBs and Type B RCBOs are able to provide protection in case of alternating residual sinusoidal currents up to 1 000 Hz, pulsating direct residual currents and smooth direct residual currents.
OVE EN 62423
2024 01 01
Fehlerstrom-/Differenzstrom-Schutzschalter Typ F und Typ B mit und ohne eingebautem Überstromschutz ...
Norm
OVE EN 62423
2024 01 01
Type F and type B residual current operated circuit-breakers with and without integral overcurrent p...
Norm
OVE EN 62423
2022 04 01
Type F and type B residual current operated circuit-breakers with and without integral overcurrent p...
Norm
ÖVE/ÖNORM EN 62423
2013 09 01
Type F and type B residual current operated circuit-breakers with and without integral overcurrent p...
Norm
ÖVE/ÖNORM EN 62423
2013 09 01
Fehlerstrom-/Differenzstrom-Schutzschalter Typ F und Typ B mit und ohne eingebautem Überstromschutz ...
Norm
ÖVE/ÖNORM EN 62423
2010 09 01
Type B residual current operated circuit-breakers with and without integral overcurrent protection f...
Norm
ÖVE/ÖNORM EN 62423
2010 09 01
Typ B Fehlerstrom-/Differenzstrom-Schutzschalter mit und ohne eingebautem Überstromschutz für Hausin...
Norm
Historie aufklappen
Norm
OVE EN 62423
Ausgabedatum : 2024 01 01
Fehlerstrom-/Differenzstrom-Schutzschalter Typ F und Typ B mit und ohne eingebautem Überstromschutz für Hausinstallationen und für ähnliche Anwendungen (deutsche Fassung)
Norm
OVE EN 62423
Ausgabedatum : 2024 01 01
Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses (english version)