Electromagnetic compatibility and Radio spectrum Matters (ERM) - Short Range Devices (SRD) - Ground- and Wall- Probing Radar applications - Part 1: Technical characteristics and test methods

The present document specifies the requirements for Ground- and Wall- Probing Radar applications operating in all or part of the frequency band from 30 MHz to 12,4 GHz. ...
Weiterlesen
ZURÜCKGEZOGEN : 2008 05 01
Herausgeber:
Austrian Standards International
Format:
Digital | 22 Seiten
Sprache:
Englisch
The present document specifies the requirements for Ground- and Wall- Probing Radar applications operating in all or part of the frequency band from 30 MHz to 12,4 GHz. Ground Probing Radars (GPR) and Wall Probing Radars (WPR) are used in survey and detection applications. The scope is limited to radars operated as short range devices (because of their usage and design), in which the system is in close proximity to the materials being investigated. It does not include radars operated from aircraft or spacecraft. The radar applications in the present document are not intended for communications purposes. Their intended usage excludes radiation into the free space and means shall be taken to keep it to a minimum. NOTE 1: Equipment using the frequencies typically below 100 MHz may use higher output power for geophysical applications and therefore, may not fulfil the emission requirements set out in the present document. NOTE 2: Equipment covered by the present document is used by competent professional personnel. The present document applies to: 1) Ground Probing Radars (GPR) operating over approximately one decade in the frequency range 30 MHz to 12,4 GHz radiating directly downwards into the ground. Any horizontal radiation from this equipment is caused by leakage and is considered as undesired emission. 2) Wall Probing Radars (WPR) operating in the frequency range 30 MHz to 12,4 GHz radiating directly into a "wall". The "wall" is a building material structure, the side of a bridge, the wall of a mine or another physical structure that absorbs a significant part of the signal transmitted by the radar. 3) Equipment fitted with integral antennas and without antenna connector. 4) Equipment which uses different imaging heads (antennas) with an antenna connector, to allow operation at different frequencies. The present document does not necessarily include all the characteristics which may be required by a user, nor does it necessarily represent the optimum performance achievable. The present document contains the technical characteristics and test methods for Ground- and Wall- Probing Radar applications.
ÖVE/ÖNORM EN 302066 V2.2.1
2020 08 01
Short Range Devices (SRD); Ground- and Wall- Probing Radio determination (GPR/WPR) devices; Harmonis...
Norm
ÖVE/ÖNORM EN 302066 V2.1.1
2017 03 01
Short Range Devices (SRD); Ground- and Wall- Probing Radar applications (GPR/WPR) imaging systems; H...
Norm
ÖVE/ÖNORM EN 302066-1 V1.2.1
2008 05 01
Electromagnetic compatibility and Radio spectrum Matters (ERM) - Ground- and Wall- Probing Radar app...
Norm
ÖNORM EN 302066-1 V 1.1.1
2005 11 01
Electromagnetic compatibility and Radio spectrum Matters (ERM) - Short Range Devices (SRD) - Ground-...
Norm
Historie aufklappen
Norm
ÖVE/ÖNORM EN 302066-1 V1.2.1
Ausgabedatum : 2008 05 01
Electromagnetic compatibility and Radio spectrum Matters (ERM) - Ground- and Wall- Probing Radar applications (GPR/WPR) imaging systems - Part 1: Technical characteristics and test methods (ETSI EN 302066-1 V1.2.1 (2008-02))