Jetzt auswählen und bestellen
69,00 €
exkl. USt.
Konfigurieren
Norm

ASTM E 648a

Ausgabedatum: 2009

Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source(2. revision 2009)

1.1 This fire-test-response standard covers a procedure for measuring the critical radiant flux of horizontally mounted floor-covering systems exposed to a flaming igniti...
Weiterlesen
Herausgeber:
American Society for Testing and Materials
Format:
Digital | 16 Seiten
Sprache:
Englisch
Aktuell Gültig:
1.1 This fire-test-response standard covers a procedure for measuring the critical radiant flux of horizontally mounted floor-covering systems exposed to a flaming ignition source in a graded radiant heat energy environment in a test chamber. A specimen is mounted over underlayment, a simulated concrete structural floor, bonded to a simulated structural floor, or otherwise mounted in a typical and representative way. 1.2 This fire-test-response standard measures the critical radiant flux at flame-out. It provides a basis for estimating one aspect of fire exposure behavior for floor-covering systems. The imposed radiant flux simulates the thermal radiation levels likely to impinge on the floors of a building whose upper surfaces are heated by flames or hot gases, or both, from a fully developed fire in an adjacent room or compartment. The standard was developed to simulate an important fire exposure component of fires that develop in corridors or exitways of buildings and is not intended for routine use in estimating flame spread behavior of floor covering in building areas other than corridors or exitways. See Appendix X1 for information on proper application and interpretation of experimental results from use of this test. 1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.4 The text of this standard references notes and footnotes that provide explanatory information. These notes and footnotes, excluding those in tables and figures, shall not be considered as requirements of this standard. 1.5 This standard is used to measure and describe the response of materials, products, or assemblies to heat and flame under controlled conditions but does not by itself incorporate all factors required for fire-hazard or fire-risk assessment of materials, products, or assemblies under actual fire conditions.. 1.6 This standard does not purport to addre ....(abbreviated)
ASTM E 648
2010
Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy...
Norm
ASTM E 648
2023 11 01
Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Ener...
Norm
ASTM E 648
2019 07 01
Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Ener...
Norm
ASTM E 648a
2017 12 01
Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Ener...
Norm
ASTM E 648
2014 04 01
Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Ener...
Norm
ASTM E 648a
2009
Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy...
Norm
Historie aufklappen
Norm
ASTM E 648
Ausgabedatum : 2010
Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source
Norm
ASTM E 648a
Ausgabedatum : 2017 12 01
Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source