Please select and order
€120.67
excl. VAT
CONFIGURE NOW
Norm

ÖNORM EN ISO 5167-4

Issue date: 2023 02 15

Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 4: Venturi tubes (ISO 5167-4:2022)

This document specifies the geometry and method of use (installation and operating conditions) of Venturi tubes) when they are inserted in a conduit running full to deter...
Read more
Valid
Publisher:
Austrian Standards International
Format:
Digital | 36 Pages
Language:
German | English | Download GER/ENG
This document specifies the geometry and method of use (installation and operating conditions) of Venturi tubes) when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. This document also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167-1. This document is applicable only to Venturi tubes in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. In addition, Venturi tubes can only be used uncalibrated in accordance with this standard within specified limits of pipe size, roughness, diameter ratio and Reynolds number, or alternatively they can be used across their calibrated range. This document is not applicable to the measurement of pulsating flow. It does not cover the use of uncalibrated Venturi tubes in pipes sized less than 50 mm or more than 1 200 mm, or where the pipe Reynolds numbers are below 2 × 10^(5). This document deals with the three types of classical Venturi tubes: a) “as cast”; b) machined; c) fabricated (also known as “rough-welded sheet-iron”). A Venturi tube consists of a convergent inlet connected to a cylindrical throat which is in turn connected to a conical expanding section called the divergent section (or alternatively the diffuser). Venturi nozzles (and other nozzles) are dealt with in ISO 5167-3.
ÖNORM EN ISO 5167-4
2023 02 15
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-secti...
Norm
ÖNORM EN ISO 5167-4
2003 12 01
Measurement of fluid flow by means of pressure differential devices inserted in ciruclar cross-secti...
Norm
ÖNORM EN ISO 5167-1/A1
1998 08 01
Measurement of fluid flow by means of pressure differential devices - Part 1: Orifice plates, nozzle...
Norm
ÖNORM EN ISO 5167-1
1996 04 01
Measurement of fluid flow by means of pressure differential devices - Part 1: Orifice plates, nozzle...
Norm
ÖNORM DIN 1952
1991 01 01
Measurement of fluid flow by means of orfice plates, nozzles and venturi tubes inserted in circular ...
Norm
ÖNORM DIN 1952
1973 02 01
Flow measurement with standardized nozzles, orifices and venturi nozzles (VDI-rules for measurement ...
Norm
Historie aufklappen
Norm
ISO 4006:1991
Issue date : 1991 05 16
Measurement of fluid flow in closed conduits — Vocabulary and symbols
Norm
ISO 5167-1:2003
Issue date : 2003 02 24
Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 1: General principles and requirements
Norm
ISO 5168:2005
Issue date : 2005 06 15
Measurement of fluid flow — Procedures for the evaluation of uncertainties
Technische Regel
ISO/IEC Guide 98-3:2008
Issue date : 2008 09 30
Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) (Corrected version 2010-11)