NORM

ZURÜCKGEZOGEN

ÖNORM EN ISO 80601-2-56

Erscheinungsdatum: 2018 01 01

Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement (ISO 80601-2-56:2017)

This document applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of a CLINICAL THERMOMETER in combination with its ACCESSORIES, hereafter referred to as ME EQUIPMENT. This document specifies the general and technical requirements for electrical CLINICAL THERMOMETERS. This document applies to all electrical CLINICAL THERMOMETERS that are used for measuring the BODY TEMPERATURE of PATIENTS. CLINICAL THERMOMETERS can be equipped with interfaces to accommodate secondary indicators, printing equipment, and other auxiliary equipment to create ME SYSTEMS. This document does not apply to auxiliary equipment. ME EQUIPMENT that measures a BODY TEMPERATURE is inside the scope of this document. This document does not specify the requirements for screening thermographs intended to be used for the individual non-invasive human febrile temperature screening of groups of individual humans under indoor environmental conditions, which are given in IEC 80601-2-59. If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME EQUIPMENT and to ME SYSTEMS, as relevant. HAZARDS inherent in the intended physiological function of ME EQUIPMENT or ME SYSTEMS within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005+A1:2012, 7.2.13 and 8.4.1.

Allgemeine Information zur ÖNORM EN ISO 80601-2-56

Format
Digital | 69 Seiten
Sprache
German | English | Download GER/ENG
Herausgeber
Austrian Standards International

Historie

Eine Übersicht über die Entwicklung der ÖNORM EN ISO 80601-2-56 von 2000 bis heute.

Häufige Fragen zu ÖNORM EN ISO 80601-2-56

When you purchase a standard from the Austrian Standards webshop (e.g. ÖNORM, ISO), a single-user licence is included as standard. This entitles a single person to use the standard. A multi-user licence is required if several employees need access. It enables company-wide, legally compliant use and sharing of standards.

Find out more about the benefits of multi-user licences

Standardization thrives on expertise and participation. Anyone interested can play an active role in its further development – for example, by joining the relevant committee or a working group. In this way, you can help shape the content and contribute to advancing the state of the art.

Find out more about getting involved in standardization

If you have an extensive portfolio of standards, we recommend using a professional standards management tool. With effects 2.0, you can manage your standards centrally and efficiently. You can optimise your procurement processes and benefit from an integrated information and subscription service. This ensures you are always up to date and never miss any relevant developments.

Find out more about the benefits of effects 2.0

Normative Verweise

Hier finden Sie einen Auszug der normativen Verweise. Die vollständige Liste entnehmen Sie bitte dem Dokument selbst.

Dokumentnummer Titel Ausgabedatum Art Link
Dokumentnummer
ISO 14155:2011
Titel
Clinical investigation of medical devices for human subjects — Good clinical practice
Ausgabedatum
2011 01 21
Art
Norm
Dokumentnummer
ISO 14937:2009
Titel
Sterilization of health care products — General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices
Ausgabedatum
2009 10 14
Art
Norm
Dokumentnummer
ISO 15223-1:2016
Titel
Medical devices — Symbols to be used with medical device labels, labelling and information to be supplied — Part 1: General requirements (Corrected version 2017-03)
Ausgabedatum
2016 11 02
Art
Norm
Dokumentnummer
ISO 17664:2004
Titel
Sterilization of medical devices — Information to be provided by the manufacturer for the processing of resterilizable medical devices
Ausgabedatum
2004 02 25
Art
Norm

Zuletzt angesehen

ÖVE/ÖNORM EN 61514-2

Industrial process control systems - Part 2: Methods of evaluating the performance of intelligent valve positioners with pneumatic outputs mounted on an actuator valve assembly (IEC 61514-2:2013)

ÖVE/ÖNORM EN 133200

Sectional Specification: Passive filter units for electromagnetic interference suppression (Filters for which safety tests are required)

ÖNORM EN ISO 20776-1

Clinical laboratory testing and in vitro diagnostic test systems - Susceptibility testing of infectious agents and evaluation of performance of antimicrobial susceptibility test devices - Part 1: Reference method for testing the in vitro activity of antimicrobial agents against rapidly growing aerobic bacteria involved in infectious diseases (ISO 20776-1:2006)
€173.27
exkl. USt.
€190.60
inkl. 10% USt.
Norm
ÖNORM EN ISO 80601-2-56 - Medical electrical equipment - Part 2-56: Particular requirements for basic safety and essential performance of clinical thermometers for body temperature measurement (ISO 80601-2-56:2017)

Single-User-Lizenz anpassen und kaufen

€173.27
exkl. USt.
€190.60
inkl. 10% USt.

Normen abonnieren

Ihr Warenkorb ist leer

Unsere Empfehlung für Sie

Norm
ÖNORM EN ISO 9001 - Quality management systems - Requirements (ISO 9001:2026)
Details ansehen
Seminar [Live-Online]
€749.00
exkl. USt.
€898.80
inkl. 20% USt.
Details ansehen
Seminar [Hybrid]
€675.00
exkl. USt.
€810.00
inkl. 20% USt.
Details ansehen
€49.00
exkl. USt.
€58.80
inkl. 20% USt.
Details ansehen
€2,419.00
exkl. USt.
€2,902.80
inkl. 20% USt.
Details ansehen